Our longest continuous field test is 25 years. As a paint manufacturer we regularly test our products. But lab tests seldom reflect real objects. That is why we choose to have third part testers making practical field tests for us. Below you find listed the tests done. And a description of purpose and length of the test. Throughout it has been shown that Isotrol Primer are giving exceptional results on rusty surfaces.
Test | Started | Period | Commentary | Test | Started | Period | Commentary |
---|---|---|---|
CPA Corrosion and Painting Assistance AB | |||
2018 | 15 y | Investigation and status of Isotrol paint system after 15 years.Field test 15 years in corrosivity C3 Evaluation of EN-ISO 4628 (Report CPA 504-2, in Swedish summary in English). | |
The Swedish Defense Material Administration | |||
1991 | 14 y | Painted Rusty (ISO 8501-1 Rust Degree C/ St 2) test panels. Outdoor exposure test at C4 corrosivity marine test station. Adhesion, degree of rust (SS185111/EN-ISO 4628-2), blistering (SS 184193/EN-ISO 4628-3). | |
1991 | 10 y | Repainting of a steel bridge | |
The Finnish national oil company | |||
1981 | 2 y | Outdoor testing at Nådendal (Finland) Comparison of competitive systems |
|
SP Technical Research Institute (RISE, Sweden) | |||
1982 | 1200 h | Salt spray test. SS 184190 / ISO 9227 / ASTM B117 Painted rusty (ISO 8501-1 Rust Degree C/ St 2) test panels. |
|
1983 | – | Adhesion test. SS 184171 / EN-ISO 4624 /ASTM D 4541 | |
2002 | 1700 h | Evaluation of available rust protective systems for maintenance painting of historical monuments; EN ISO 12944 Accelerated testing (ISO 9227/ /ASTM B117, ISO 11997-2/VDA 611). Results Blistering ISO 4628-3.(SP Report 2002:07 and 2002:14.) | |
2004 | 1 y | Evaluation of available rust protective systems for maintenance painting of historical monuments – health and environmental hazards. (SP Report 2004:26) | |
2006 | 2 y | Evaluation of available rust protective systems for maintenance painting of historical monuments – Results of accelerated testing. (SP Report 2006:05) | |
2007 | 3 y | Evaluation of available rust protective systems for maintenance painting of historical monuments – Results of field station testing and comparison with accelerated test. (SP-Work report 2007:01) | 2013 | 10 y | Comparison between protective paint systems: Two old repainted steel bridges after 10 years (SP Report 2013-38-sw) |
Swerea KIMAB (Swedish corrosion institute) | |||
1984 | 80 d | Painted rusty (ISO 8501-1 Rust Degree C/ St 2) test panels. Outdoor exposure test at C4 marine test station. | |
1993 | 4300 h | ISO 11474. Accelerated outdoor test by intermittent spraying of salt solution (SCAB). Corrosion of metals and alloys – corrosion tests in artificial atmosphere. | |
2002 | 13 y | Overcoating of structures painted with lead-based paint – an alternative strategy in corrosion protection maintenance (2002:4 sw) Extract in Eng. | |
2006 | – | Repainting of four power towers along KL 2 S4 Ljusdal-Dönje (730877-38) sw | |
2010 | 10-20 y | Optimized maintenance of steel bridges. Painting status of modern steel bridges in Sweden New maintenance strategy suggested (Report 2010-130 sw). (Summary in Eng.) | |
2014 | 5-25 y | Repainting of red lead painted objects (2014-129) Recommendations for overpainting old paintings containing red lead (sw). Abstract in Eng. | |
Vattenfall AB Swedish Water Power Production | |||
1990 | 7 y | Long-term testing of corrosion paint in atmosphere ISSN 1100-5130. Outdoor exposure test at C3 marine test station. |